{"product_id":"lqse22dalunvd","title":"Módulo de Alimentación DALI-2 \/ HomeWorks Universal \/ 2 Buses DALI Independientes \/ 64 Cargas Direccionables por Bus \/ Riel DIN 9 Módulos (161.7 mm) \/ 100-277 V~ 50\/60 Hz \/ Certificado DALI-2 IEC 62386-101 y 103 \/ Protección co","description":"\u003cdiv style=\"width: 100%; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e\n\u003cdiv style=\"margin-bottom: 30px;\"\u003e\n\u003ch2 style=\"font-size: 28px; margin-bottom: 10px; color: inherit; font-weight: normal;\"\u003e\n\u003cstrong style=\"font-weight: bold;\"\u003eLutron modelo:\u003c\/strong\u003e LQSE2-2DALUNV-D\u003c\/h2\u003e\n\u003cp style=\"text-align: justify; font-size: 16px; color: inherit; opacity: 0.9;\"\u003eEl módulo de alimentación eléctrica DALI® HomeWorks Universal de Lutron es un controlador maestro individual de aplicaciones certificado para DALI-2® por la Digital Illumination Interface Alliance® (DiiA®)\u0026amp;comma; diseñado para montaje en riel DIN y uso con cargas direccionables digitales compatibles con DALI® en sistemas HomeWorks QSX y HomeWorks QS. Suministra alimentación eléctrica DALI® y control de bus para dos buses DALI® independientes\u0026amp;comma; admitiendo hasta 64 cargas digitales accesibles por dirección compatibles con DALI® en cada bus\u0026amp;comma; lo que permite un total de 128 cargas direccionables. Incorpora una fuente de alimentación de bus integrada que entrega una corriente garantizada de 128 mA (máximo de 250 mA) por bus\u0026amp;comma; con protección contra cortocircuitos y reinicio automático. El dispositivo admite tiempos de atenuación estándar DALI® IEC 62386-102\u0026amp;comma; cargas de emergencia autónomas DALI® IEC 62386-202 (Tipo 1) y cargas blancas ajustables (tc) DALI® IEC 62386-209 (Tipo 8)\u0026amp;comma; además de control de la intensidad percibida y asignación dinámica de grupos DALI®. Su arquitectura de terminales separa el cableado de red eléctrica de los circuitos PELV\u0026amp;comma; y cuenta con protección contra caída de rayos conforme a ANSI\/IEEE 62.31-1980 soportando picos de hasta 6000 V~ y 3000 A. Está orientado a integradores e ingenieros que requieren control de iluminación direccionable de alta fiabilidad en instalaciones comerciales\u0026amp;comma; institucionales y de iluminación de emergencia.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003e\u003cspan style=\"font-size: 24px;\"\u003eCaracterísticas Generales\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eTipo de producto:\u003c\/strong\u003e Módulo de alimentación eléctrica DALI® \/ Controlador maestro individual de aplicaciones\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eCertificación:\u003c\/strong\u003e DALI-2® por la Digital Illumination Interface Alliance® (DiiA®)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eSistemas compatibles:\u003c\/strong\u003e HomeWorks QSX y HomeWorks QS (versión 15.11 o superior)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eNº de buses DALI® admitidos:\u003c\/strong\u003e 2 (independientes)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eCargas DALI® por bus:\u003c\/strong\u003e Hasta 64 cargas direccionables digitales compatibles con DALI®\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eZonas de Lutron por bus:\u003c\/strong\u003e 64 (HomeWorks QSX) \/ 16 (HomeWorks QS)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eMontaje:\u003c\/strong\u003e Riel DIN\u0026amp;comma; 9 módulos DIN (161.7 mm)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eRegión:\u003c\/strong\u003e Para regiones ubicadas fuera de Norteamérica\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150\u0026amp;comma; 150\u0026amp;comma; 150\u0026amp;comma; 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150\u0026amp;comma; 150\u0026amp;comma; 150\u0026amp;comma; 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003e\u003cspan style=\"font-size: 24px;\"\u003eFuncionalidad\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\n\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eControlador maestro DALI®:\u003c\/strong\u003e Individual de aplicaciones (QSX y QS)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eTiempos de atenuación estándar DALI®:\u003c\/strong\u003e IEC 62386-102 (QSX y QS)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eTiempo de desvanecimiento:\u003c\/strong\u003e Hasta 4 horas (solo QSX)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eCargas de emergencia autónomas DALI®:\u003c\/strong\u003e IEC 62386-202 (Tipo 1) (QSX y QS)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eCargas blancas ajustables (tc) DALI®:\u003c\/strong\u003e IEC 62386-209 (Tipo 8) (solo QSX)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eCargas blancas ajustables de doble canal:\u003c\/strong\u003e Solo QS\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eControl de intensidad percibida:\u003c\/strong\u003e Sí (QSX y QS)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eControl simultáneo de color e intensidad:\u003c\/strong\u003e Con tiempos de desvanecimiento independientes (solo QSX)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eAsignación dinámica de grupos DALI®:\u003c\/strong\u003e Sí (solo QSX)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eConfiguración en terreno:\u003c\/strong\u003e Nivel de falla del sistema\u0026amp;comma; niveles mínimos\/máximos y tiempos de desvanecimiento\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eMemoria de fallas de alimentación:\u003c\/strong\u003e Retiene la programación del equipo de control ante interrupción del suministro\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eActualización de firmware:\u003c\/strong\u003e Las luces permanecen inalteradas durante la actualización\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 12px; opacity: 0.7; margin-top: 10px;\"\u003e*Notas: La salida efectiva de la temperatura de color está determinada por la tolerancia del controlador de terceros. La asignación dinámica de grupos DALI® asigna zonas de forma automática e inteligente a grupos DALI® para maximizar el desempeño de atenuación y minimizar el comportamiento asincrónico de las cargas dentro de una zona.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150\u0026amp;comma; 150\u0026amp;comma; 150\u0026amp;comma; 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150\u0026amp;comma; 150\u0026amp;comma; 150\u0026amp;comma; 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003e\u003cspan style=\"font-size: 24px;\"\u003eAlimentación y Buses DALI®\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003e100 V~:\u003c\/strong\u003e 50\/60 Hz\u0026amp;comma; 150 mA\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003e120 V~:\u003c\/strong\u003e 50\/60 Hz\u0026amp;comma; 120 mA\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003e220-240 V~:\u003c\/strong\u003e 50\/60 Hz\u0026amp;comma; 80 mA\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003e277 V~:\u003c\/strong\u003e 50\/60 Hz\u0026amp;comma; 70 mA\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eSalida del bus DALI®:\u003c\/strong\u003e 16 V-\u0026amp;comma; 128 mA de corriente de suministro garantizada\u0026amp;comma; 250 mA máxima por bus\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eProtección contra caída de rayos:\u003c\/strong\u003e ANSI\/IEEE 62.31-1980; picos de voltaje hasta 6000 V~ y picos de corriente hasta 3000 A\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eProtección contra cortocircuitos:\u003c\/strong\u003e Con reinicio automático (retardo de apagado de 610 ms con reinicio de 3 segundos\u0026amp;comma; seguido de retardo de apagado de 800 ms con tiempo de reintento de 160 ms)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eControlador maestro exclusivo:\u003c\/strong\u003e No pueden existir otros controladores o sensores en el mismo bus DALI®\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003ePolaridad:\u003c\/strong\u003e Algunas cargas DALI® pueden ser sensibles a la polaridad\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150\u0026amp;comma; 150\u0026amp;comma; 150\u0026amp;comma; 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150\u0026amp;comma; 150\u0026amp;comma; 150\u0026amp;comma; 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003e\u003cspan style=\"font-size: 24px;\"\u003eFísicas y Eléctricas\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eDimensiones:\u003c\/strong\u003e 161.7 mm (6.375 in) x 89.7 mm (3.5 in) x 60.6 mm (2.375 in)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eMódulos DIN:\u003c\/strong\u003e Nueve (161.7 mm)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eTemp. Operación:\u003c\/strong\u003e 0 ºC a 40 ºC (32 ºF a 104 ºF)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eHumedad relativa:\u003c\/strong\u003e Menor que 90% sin condensación\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eUso:\u003c\/strong\u003e Sólo para uso bajo techo\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eMontaje:\u003c\/strong\u003e Dentro de un panel de consumo IP20 (mínimo) homologado o panel de disyuntores con riel DIN integrado y tapa fija\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eCableado de red eléctrica:\u003c\/strong\u003e 1\u0026amp;comma;0 mm² a 4\u0026amp;comma;0 mm² (18 AWG a 12 AWG)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eConexión del bus DALI®:\u003c\/strong\u003e 0\u0026amp;comma;5 mm² a 4\u0026amp;comma;0 mm² (20 AWG a 12 AWG)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eCableado del enlace QS:\u003c\/strong\u003e 0\u0026amp;comma;5 mm² a 2\u0026amp;comma;5 mm² (20 AWG a 12 AWG)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eCableado de CCI y CCI de Emergencia:\u003c\/strong\u003e 0\u0026amp;comma;5 mm² a 1\u0026amp;comma;5 mm² (20 AWG a 16 AWG)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eTorque del terminal:\u003c\/strong\u003e 0\u0026amp;comma;6 N•m (5.0 in-lb)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eCalibre de conductores:\u003c\/strong\u003e 60 ºC\/75 ºC Cu \/ Al; pelado 8\u0026amp;comma;0 mm (5\/16 in)\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150\u0026amp;comma; 150\u0026amp;comma; 150\u0026amp;comma; 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150\u0026amp;comma; 150\u0026amp;comma; 150\u0026amp;comma; 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003e\u003cspan style=\"font-size: 24px;\"\u003eNormas y Certificaciones\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003eSistemas de calidad de Lutron registrados en ISO 9001:2015\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003eIEC 60669-2-5\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003eCertificado para DALI-2®\u0026amp;comma; IEC 62386-101 y IEC 62386-103 ed. 2\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003eCertificado por NOM\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003eICES-3(B) \/ NMB-3(B)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003eFCC Parte 15\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003eListado por cULus\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003eUL® 924\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150\u0026amp;comma; 150\u0026amp;comma; 150\u0026amp;comma; 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150\u0026amp;comma; 150\u0026amp;comma; 150\u0026amp;comma; 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003e\u003cspan style=\"font-size: 24px;\"\u003eLongitudes de Cableado\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\n\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eBus DALI® 1\u0026amp;comma;5 mm² (16 AWG):\u003c\/strong\u003e 300 m (984 pies)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eBus DALI® 0\u0026amp;comma;75 mm² (20 AWG):\u003c\/strong\u003e 150 m (492 pies)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eBus DALI® 0\u0026amp;comma;50 mm² (22 AWG):\u003c\/strong\u003e 100 m (328 pies)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eCaída máxima en bus DALI®:\u003c\/strong\u003e No más de 2 V entre el módulo y el extremo del bus\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eEnlace QS (total):\u003c\/strong\u003e No debe exceder 610 m (2000 pies)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eEnlace QS \u0026lt; 153 m (502 pies):\u003c\/strong\u003e Alimentación 1\u0026amp;comma;0 mm² (18 AWG); Datos par retorcido y blindado 0\u0026amp;comma;5 mm² (22 AWG)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eEnlace QS 153 m a 610 m (502 a 2000 pies):\u003c\/strong\u003e Alimentación 4\u0026amp;comma;0 mm² (12 AWG); Datos par retorcido y blindado 0\u0026amp;comma;5 mm² (22 AWG)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eTopología del enlace QS:\u003c\/strong\u003e Concatenado en margarita o toma en T\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 12px; opacity: 0.7; margin-top: 10px;\"\u003e*Notas: El cableado del DALI® no es SELV; es tratado como voltaje de red y puede circular dentro de la misma vaina. Respete las normativas locales y nacionales para evitar la violación de las pautas de separación requeridas.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150\u0026amp;comma; 150\u0026amp;comma; 150\u0026amp;comma; 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150\u0026amp;comma; 150\u0026amp;comma; 150\u0026amp;comma; 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003e\u003cspan style=\"font-size: 24px;\"\u003eEntradas de Cierre de Contactos\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eCCI de control manual (IEC PELV \/ NEC® Clase 2):\u003c\/strong\u003e El dispositivo conectado debe proporcionar un cierre de contactos seco cerrado o salida de estado sólido\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eProtección de entrada:\u003c\/strong\u003e Protegida contra errores de cableado hasta 36 V-\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003ePuente preinstalado:\u003c\/strong\u003e Se envía con un puente preinstalado en la entrada de cierre de contactos de Emergencia\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eModo de control manual:\u003c\/strong\u003e Se activa abriendo el cierre de contactos de Emergencia (requiere quitar el puente preinstalado)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eCCI programable (IEC PELV \/ NEC® Clase 2):\u003c\/strong\u003e Acepta cierre de contactos seco\u0026amp;comma; salida de estado sólido\u0026amp;comma; colector abierto o salida NPN\/PNP\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eNPN \/ activo bajo:\u003c\/strong\u003e Voltaje menor que 1 V- y corriente de drenaje 3\u0026amp;comma;0 mA\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003ePNP \/ activo alto:\u003c\/strong\u003e Voltaje mayor que 12 V- y corriente de fuente 3\u0026amp;comma;0 mA\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eTiempo de reconocimiento:\u003c\/strong\u003e Las salidas deben permanecer cerradas o abiertas por lo menos 40 mseg\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150\u0026amp;comma; 150\u0026amp;comma; 150\u0026amp;comma; 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150\u0026amp;comma; 150\u0026amp;comma; 150\u0026amp;comma; 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003e\u003cspan style=\"font-size: 24px;\"\u003eSolución de Problemas y Mantenimiento\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003eMantiene memoria redundante de la programación de los elementos de control para facilitar el reemplazo de controles individuales y múltiples\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003eLuego de la instalación\u0026amp;comma; el botón \"TEST\" verifica el cableado de DALI® en todos los artefactos\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150\u0026amp;comma; 150\u0026amp;comma; 150\u0026amp;comma; 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150\u0026amp;comma; 150\u0026amp;comma; 150\u0026amp;comma; 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003e\u003cspan style=\"font-size: 24px;\"\u003eAplicaciones de Iluminación de Emergencia\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003eUtilizan sólo alimentación eléctrica normal (no esencial)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003eCuando se interrumpe la alimentación normal\u0026amp;comma; el módulo de alimentación eléctrica DALI® no alimenta los buses DALI®\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003eLos elementos de control energizados por las alimentaciones de emergencia pasan a su nivel de falla del sistema (salida plena de luz como acción predeterminada)\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150\u0026amp;comma; 150\u0026amp;comma; 150\u0026amp;comma; 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150\u0026amp;comma; 150\u0026amp;comma; 150\u0026amp;comma; 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003e\u003cspan style=\"font-size: 24px;\"\u003eContenido del Paquete\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003eMódulo de alimentación eléctrica DALI® HomeWorks Universal LQSE2-2DALUNV-D\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003ePuente preinstalado en la entrada de cierre de contactos de Emergencia\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px; color: inherit;\"\u003e\u003cdiv style=\"flex: 1 1 200px;\"\u003e\u003ch4 style=\"font-size: 16px; font-weight: bold; text-transform: uppercase; opacity: 0.8; color: inherit;\"\u003e\u003cbr\u003e\u003c\/h4\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"LUTRON ELECTRONICS","offers":[{"title":"Default Title","offer_id":48844353863798,"sku":"LQSE22DALUNVD","price":25869.81,"currency_code":"MXN","in_stock":false}],"url":"https:\/\/fluxtec.mx\/products\/lqse22dalunvd","provider":"FluxTec","version":"1.0","type":"link"}